Meeting rooms, activity rooms, rest rooms, locker rooms and other places are located within the area affected by the lifting and transporting of molten iron, molten steel and liquid slag.
-
Cranes used for lifting molten iron, molten steel and liquid slag do not meet the relevant requirements for metallurgical cranes; in steelmaking plants, when lifting heavy ladles of molten iron, molten steel or liquid slag, fixed gantry hook casting cranes are not used; the gantry hook crossbeam, trunnion pins, hooks, wire ropes and their end fixing parts are not periodically inspected, and identified problems are not promptly rectified.
-
The trunnions of vessels (such as ladles, pots and basins) containing molten iron, لا يخضع الفولاذ المنصهر والخبث السائل للاختبارات الدورية غير المدمرة كما هو مطلوب بموجب المعايير الوطنية.
-
وجود المياه المتراكمة والمواد القابلة للاشتعال والانفجار في حفر الأمان وضمن المنطقة المتضررة من تسرب الصهر والتناثر في الصهر, مناطق إنتاج الصهر والتكرير. في صب المعادن, عمليات الصب والصب المستمر, مرافق التفريغ في حالات الطوارئ وتخزين الطوارئ للمعادن المنصهرة ذات درجة الحرارة العالية, مثل مغارف الحديد المنصهر, مغارف من الفولاذ المنصهر, أحواض الفائض وخزانات الفائض المتوسطة, لم يتم توفيرها.
-
الهيئات الرئيسية والمرافق المساعدة للأفران, أفران, ولا يتم تفتيش الدبابات والسفن بشكل دوري; ويستمر استخدامها دون الإبلاغ عن الإصلاح أو التخريد عند حدوث تشققات خطيرة في اللحام, تآكل, ضرر, تدهور بطانة الطوب, shell reddening and obvious bending deformation occur.
-
Water-cooled elements such as oxygen lances are not equipped with detection and alarm devices for outlet water temperature and inlet-outlet water flow difference, as well as temperature monitoring, and are not interlocked with furnace tilting, oxygen opening/closing, إلخ.
-
Gas holders are constructed in densely populated areas and are not located away from important facilities such as large buildings, warehouses, communication and transportation hubs; auxiliary equipment and facilities are not equipped with explosion-proof devices according to fire and explosion protection requirements; lightning protection devices are not installed on the top of the gas holder.
-
لا يتم تركيب أجهزة ثابتة لمراقبة وإنذار أول أكسيد الكربون في الأماكن التي يتركز فيها الأفراد في مناطق الغاز, مثل غرف العمل وغرف العمليات.
-
لا يتم توفير أجهزة عزل موثوقة ومرافق تطهير على خطوط أنابيب الغاز للأفران العالية, المحولات, أفران إعادة التسخين, أصحاب الغاز, جامعي الغبار وغيرها من المرافق.
-
لا يتم تركيب أجهزة إغلاق موثوقة عند توصيلات الأنابيب الفرعية الموجودة على رأس توزيع الغاز الرئيسي; في ورشة العمل, لا يتم تركيب صمامات إغلاق الرأس الرئيسية عند مدخل خطوط أنابيب الغاز المختلفة.
-
لم يجتاز الشخص الرئيسي المسؤول وموظفو إدارة سلامة الإنتاج في شركات صهر المعادن التقييم كما يقتضي القانون.